Switch back to apartment threaded COM initialization, which was the previous default.
We do succeed now if the application previously initialized COM in multi-threaded mode.
parent
6f6c76a6a5
commit
6915319683
|
@ -45,7 +45,15 @@ WIN_SetError(const char *prefix)
|
|||
HRESULT
|
||||
WIN_CoInitialize(void)
|
||||
{
|
||||
const HRESULT hr = CoInitializeEx(NULL, COINIT_MULTITHREADED);
|
||||
/* SDL handles any threading model, so initialize with the default, which
|
||||
is compatible with OLE and if that doesn't work, try multi-threaded mode.
|
||||
|
||||
If you need multi-threaded mode, call CoInitializeEx() before SDL_Init()
|
||||
*/
|
||||
HRESULT hr = CoInitializeEx(NULL, COINIT_APARTMENTTHREADED);
|
||||
if (hr == RPC_E_CHANGED_MODE) {
|
||||
hr = CoInitializeEx(NULL, COINIT_MULTITHREADED);
|
||||
}
|
||||
|
||||
/* S_FALSE means success, but someone else already initialized. */
|
||||
/* You still need to call CoUninitialize in this case! */
|
||||
|
|
Loading…